Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 15.322
Filtrar
1.
Zhonghua Zhong Liu Za Zhi ; 46(5): 457-460, 2024 May 23.
Artigo em Chinês | MEDLINE | ID: mdl-38742359

RESUMO

Objective: To analyze the ultrasonic features of tonsillar lymphoma to improve the diagnostic accuracy. Methods: The clinical, pathological and ultrasonic data of nine patients with tonsillar lymphoma confirmed by pathology at Tianjin Medical University Cancer Institute and Hospital during June 2015 and June 2022 were analyzed retrospectively, and the characteristics of their ultrasonic images were summarized. Results: All 9 cases of tonsil lymphoma were unilateral tonsil disease, including 4 cases on the left side and 5 cases on the right side. The average maximum diameter of tonsil lymphoma in 9 cases was 4.32 cm. There were 3 cases with simultaneous involvement of tonsil and cervical lymph nodes, all of which were ipsilateral lymph nodes. Gray scale ultrasound showed that the lesions were hypoechoic, with clear boundaries in 7 cases and unclear boundaries in 2 cases. The shape was full and irregular in 5 cases and oval in 4 cases. The echo was uniform in 7 cases and uneven in 2 cases. Color Doppler ultrasonography showed abundant internal blood flow signal in 1 case, a little dotted linear internal blood flow signal in 5 cases, and no obvious internal blood flow signal in 3 cases. Conclusions: The ultrasonic features of tonsillar lymphoma include hypoechoic area, clear boundary, full shape, irregular and uniform internal echo, no or low linear signal of internal blood flow. Ultrasonography is of great value in the diagnosis of this disease and can help clinical decision-making.


Assuntos
Neoplasias Tonsilares , Humanos , Neoplasias Tonsilares/diagnóstico por imagem , Neoplasias Tonsilares/patologia , Estudos Retrospectivos , Linfonodos/patologia , Linfonodos/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Linfoma/diagnóstico por imagem , Linfoma/diagnóstico , Ultrassonografia/métodos , Pessoa de Meia-Idade
3.
Medicine (Baltimore) ; 103(17): e37899, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38669377

RESUMO

To investigate the clinical value of contrast-enhanced ultrasound in the prediction of hepatic encephalopathy (HE) in patients with hepatitis B cirrhosis after intrahepatic portal-systemic shunt via jugular vein. In this retrospective study, we collected data from 75 patients with hepatitis B, cirrhosis, and portal hypertension who underwent jugular intrahepatic portosystemic shunt from February 2019 to February 2022. The diagnostic instrument used was the TOSHIBA Aplio500 color Doppler ultrasound with contrast-enhanced ultrasound capabilities. The trial group comprised 20 patients with HE within 3 months postsurgery, while the control group (CG) included 55 patients without HE within the same postoperative period. All patients underwent various examinations before and within 48 hours after surgery, including observation of liver and spleen size and stent position, as well as assessment of blood flow direction in portal and hepatic veins. Subsequently, contrast-enhanced ultrasound was employed to examine and observe perfusion changes of contrast agents in hepatic veins, hepatic arteries, and portal veins (PV). Changes in PV pressure gradient, intrahepatic, and stent blood flow perfusion (BFP) were explored in both postoperative trials and CGs. The trial group exhibited higher BFP volume, PV pressure gradient difference, and percentage decrease compared to the CG. A weak positive correlation was observed between blood flow within the liver stent and PV pressure gradient difference, as well as the percentage decrease in PV pressure gradient. The correlation coefficient between blood flowing perfusion volume within the stent and the difference in PV pressure gradient was R = 0.415 (P = .000). The correlating coefficient between BFP amount within the stent and the percentage decrease in PV pressure gradient was R = 0.261 (P = .027). The area under the receiver operating characteristic curve for stent perfusion volume, difference in PV pressure gradient, and percentage decrease in PV pressure gradient was 0.691, 0.759, and 0.742, respectively. An increase in PV pressure gradient accelerates blood flow within the stent, predisposing to HE. Changes in hepatic BFP following transjugular intrahepatic portosystemic shunt can effectively predict the occurrence of HE, demonstrating significant clinical relevance.


Assuntos
Meios de Contraste , Derivação Portossistêmica Transjugular Intra-Hepática , Humanos , Masculino , Derivação Portossistêmica Transjugular Intra-Hepática/métodos , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Hipertensão Portal/cirurgia , Hipertensão Portal/fisiopatologia , Hipertensão Portal/diagnóstico por imagem , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Fígado/cirurgia , Ultrassonografia Doppler em Cores/métodos , Adulto , Cirrose Hepática/cirurgia , Cirrose Hepática/fisiopatologia , Cirrose Hepática/diagnóstico por imagem , Circulação Hepática/fisiologia , Idoso , Veia Porta/diagnóstico por imagem , Veia Porta/fisiopatologia , Relevância Clínica
4.
J Cancer Res Ther ; 20(2): 665-668, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38687938

RESUMO

AIMS: The aims of this study were to investigate the ultrasound features of non-mass-type ductal carcinoma in situ (DCIS) of the breast and conduct a pathological analysis. MATERIAL AND METHODS: Ultrasound images of 32 cases of non-mass-type DCIS of the breast, collected between September 2014 and June 2016, were analyzed. The characteristics of the lesions, including border, internal echogenicity, local glandular hyperplasia, micro-calcification, and intra-tumoral blood flow resistance index (RI), were analyzed, and a concurrent pathological analysis was conducted. RESULTS: Obvious local glandular hyperplasia was commonly observed in the 32 cases of non-mass-type DCIS of the breast. The internal echogenicity varied in intensity, exhibiting a "leopard pattern" or "zebra pattern." Color Doppler imaging revealed abundant blood flow signals within the lesion with an RI of >0.7. Isolated duct dilatation and micro-calcifications were occasionally observed within the lesions. High-grade DCIS was the predominant pathological type of non-mass-type DCIS. CONCLUSIONS: Non-mass-type DCIS of the breast often presents with obvious local glandular hyperplasia and varying internal echogenicity. High-grade DCIS is the frequent pathological type. Color Doppler imaging and RI measurement can assist in diagnosing non-mass-type DCIS of the breast.


Assuntos
Neoplasias da Mama , Carcinoma Intraductal não Infiltrante , Humanos , Feminino , Neoplasias da Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Pessoa de Meia-Idade , Carcinoma Intraductal não Infiltrante/patologia , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/diagnóstico , Idoso , Adulto , Hiperplasia/patologia , Hiperplasia/diagnóstico por imagem , Ultrassonografia Mamária/métodos , Mama/patologia , Mama/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Gradação de Tumores
5.
Artigo em Chinês | MEDLINE | ID: mdl-38548399

RESUMO

Objective: To explore the cutting scheme and clinical application effects of ultrathin thoracodorsal artery perforator flap assisted by color Doppler ultrasound. Methods: This study was a retrospective historical control study. From February 2017 to October 2019, 20 patients who were admitted to the Third Department of Orthopedics of Xingtai General Hospital of North China Medical and Health Group (hereinafter referred to as our department), met the inclusion criteria, and underwent repair of skin and soft tissue defects of extremities with ultrathin thoracodorsal artery perforator flap designed and harvested based on the surgeon's clinical experience were selected as control group, including 16 males and 4 females, aged (37±5) years. From November 2019 to December 2022, 21 patients who were admitted to our department, met the inclusion criteria, and underwent repair of skin and soft tissue defects of extremities with ultrathin thoracodorsal artery perforator flap designed and harvested under the assistance of color Doppler ultrasound were selected as ultrasound-assisted group, including 15 males and 6 females, aged (38±6) years. After debridement, the area of skin and soft tissue defects of extremities ranged 5.0 cm×4.0 cm to 19.0 cm×8.0 cm, and the area of thoracodorsal artery perforator flaps ranged 6.0 cm×5.0 cm to 20.0 cm×9.0 cm. The wounds in flap donor sites were closed directly. For patients in ultrasound-assisted group, the time and cost required for color Doppler ultrasound examination were recorded, and the number, type, and location of thoracodorsal artery perforator vessels detected by preoperative color Doppler ultrasound were compared with those of intraoperative actual detection. The time required for complete flap harvest of patients in 2 groups was recorded. On postoperative day (POD) 1, 3, 5, 7, and 14, the blood perfusion of flaps in the 2 groups of patients was assessed using a flap perfusion assessment scale. On POD 14, flap survival of patients in 2 groups was observed, and the percentage of flap survival area was calculated. In postoperative 6 months, satisfaction of patients with the treatment outcome in the 2 groups was assessed using 5-grade Likert scale, and the satisfaction rate was calculated. Results: For patients in ultrasound-assisted group, the time required for preoperative color Doppler ultrasound examination was (10.5±2.3) min, and the cost was 120 yuan; 21 thoracodorsal artery perforator vessels were detected and marked using preoperative color Doppler ultrasound, including 8 (38.10%) type 1 perforator vessels, 10 (47.62%) type 2 perforator vessels, and 3 (14.29%) type 3 perforator vessels; the number, type, and location of thoracodorsal artery perforator vessels detected preoperatively were consistent with those detected intraoperatively. The time required for complete flap harvest of patients in ultrasound-assisted group was (41±10) min, which was significantly shorter than (63±12) min in control group (t=6.32, P<0.05). On POD 1, 3, 5, 7, and 14, the blood perfusion scores of flaps of patients in ultrasound-assisted group were significantly better than those in control group (with t values of 6.67, 7.48, 8.03, 8.75, and 7.99, respectively P<0.05). On POD 14, only one patient in ultrasound-assisted group had partial flap necrosis and 6 patients in control group had complete or partial necrosis of the flap; the percentage of flap survival area of patients in ultrasound-assisted group was (99±8)%, which was significantly higher than (87±8)% in control group (t=4.57, P<0.05). In postoperative 6 months, there was no significant difference in the satisfaction rate of patients with the treatment outcome between the two groups (P>0.05). Conclusions: Preoperative color Doppler ultrasound is highly accurate in detecting the number, type, and location of perforator vessels. The cutting scheme of ultrathin thoracodorsal artery perforator flaps can be designed according to the different types of perforator vessels, with shorted flap cutting time and improved flap survival rate.


Assuntos
Retalho Perfurante , Procedimentos de Cirurgia Plástica , Masculino , Feminino , Humanos , Retalho Perfurante/irrigação sanguínea , Estudos Retrospectivos , Artérias/diagnóstico por imagem , Ultrassonografia Doppler em Cores , Necrose
6.
Med Intensiva (Engl Ed) ; 48(3): 165-173, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38431382

RESUMO

Transcranial ultrasonography is a non-invasive, bedside technique that has become a widely implemented tool in the evaluation and management of neurocritically ill patients. It constitutes a technique in continuous growth whose fundamentals (and limitations) must be known by the intensivist. This review provides a practical approach for the intensivist, including the different sonographic windows and planes of insonation and its role in different conditions of the neurocritical patients and in critical care patients of other etiologies.


Assuntos
Ultrassonografia Doppler em Cores , Ultrassonografia Doppler Transcraniana , Humanos , Ultrassonografia Doppler Transcraniana/métodos , Ultrassonografia Doppler em Cores/métodos , Ultrassonografia , Cuidados Críticos
7.
Indian Pediatr ; 61(3): 237-242, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38469839

RESUMO

OBJECTIVE: To evaluate the utility of color Doppler ultrasonography in assessing infantile hemangioma response to treatment with oral propranolol. METHODS: A prospective study was conducted between January, 2016 and December, 2022, wherein children with symptomatic (ulceration, bleeding, pain and scarring) infantile hemangioma were given oral propranol (2 mg/kg per day in three divided doses) as outpatient therapy. The clinical response was assessed three months post-initiation of treatment (intermediate clinical response) and three months post-completion of treatment (final clinical response, FCR). The primary outcome measurement was a clinical and radiological response (resistivity index (RI), pulsatility index (PI) and peak systolic velocity) to treatment. The secondary outcomes assessed were the complications related to treatment. RESULTS: Out of 601 patients who were started on propranolol, 99 developed severe adverse effects and were excluded from analysis. At FCR assessment, out of 502 participants, 64.3% (n = 323) showed excellent response, 17.7% (n = 89) showed partial, and 17.9% (n = 90) were non-responders. A significant increase in RI and PI values was noted in all children following propranolol treatment for six months. An increase > 7.5% in RI could identify responders with 92% sensitivity, 91% specificity and area under the curve (AUC) of 0.963. An increase of > 11.5% in PI could identify responders with 86% sensitivity, 91% specificity and AUC of 0.896. Patients initially showing no response but later becoming excellent responders had significantly higher RI and PI values. CONCLUSIONS: Color Doppler ultrasonography is a valuable tool in predicting the treatment outcome of infantile hemangioma using propranolol.


Assuntos
Hemangioma Capilar , Neoplasias Cutâneas , Criança , Humanos , Lactente , Propranolol/efeitos adversos , Antagonistas Adrenérgicos beta/efeitos adversos , Estudos Prospectivos , Hemangioma Capilar/induzido quimicamente , Hemangioma Capilar/tratamento farmacológico , Resultado do Tratamento , Ultrassonografia Doppler em Cores , Administração Oral , Neoplasias Cutâneas/induzido quimicamente , Neoplasias Cutâneas/tratamento farmacológico
8.
Ultrasound Med Biol ; 50(6): 970-973, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38433075

RESUMO

OBJECTIVE: To test the Doppler guide wire (DGW) for navigation of the wire positioning by color Doppler ultrasound in the setting of percutaneous coronary intervention (PCI). METHODS: An acoustically active DGW was tested in a water tank before its in vivo use. A waveform generator was connected to the DGW, and a transducer scanned the DGW to visualize a Doppler shift signal between the vibrating piezoelectric crystal located at the DGW tip and Doppler signal from the transducer as a distinct, instantaneous color marker. An intracoronary injection was tested in four male domestic pigs using an open-chest setting. A Judkins left coronary guiding catheter was inserted into the ascending aorta via the right carotid artery under B-mode ultrasound guidance. The DGW with an infusion catheter or over-the-wire (OTW) balloon catheter was inserted into the guiding catheter. The color marker instantaneously defined the DGW tip and navigated the catheter into the left anterior descending artery (LAD). RESULTS: The tip of the DGW was visualized within the guiding catheter by a distinct color marker and helped to engage the guiding catheter to the left main orifice. The DGW with an infusion or OTW balloon catheter was inserted into the LAD. We confirmed that the catheter was positioned in the proximal LAD by the colored territory perfused by an injected indigo carmine solution. CONCLUSION: Ultrasound navigation using acoustically active DGW was feasible. Our pilot study introduces a new concept of color Doppler-navigated wire positioning in the coronary artery in the setting of PCI.


Assuntos
Ultrassonografia Doppler em Cores , Ultrassonografia de Intervenção , Animais , Projetos Piloto , Suínos , Masculino , Ultrassonografia de Intervenção/métodos , Ultrassonografia Doppler em Cores/métodos , Intervenção Coronária Percutânea/métodos , Vasos Coronários/diagnóstico por imagem , Cirurgia Assistida por Computador/métodos
9.
Pediatr Cardiol ; 45(4): 710-721, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38366300

RESUMO

Atrial septal defects (ASDs) are common in neonates. Although past studies suggest ASDs  ≥ 3 mm in term neonates (TNs) are less likely to close, there is paucity of data regarding the natural history in preterm neonates (PNs), information that would inform surveillance. We sought to compare spontaneous closure rates and need for intervention for ASDs in TNs/near term (≥ 36 weeks) versus PNs (< 36 weeks). We included all TNs and PNs who underwent echocardiography at ≤ 1 month between 2010 and 2018 in our institution with an ASD ≥ 3 mm, without major congenital heart disease, and with repeat echocardiogram(s). Spontaneous resolution was defined as size diminution to < 3 mm or closure. We included 156 TNs (mean gestational age at birth 38.6 ± 1.4 weeks) and 156 PNs (29.6 ± 3.7 weeks) with a mean age at follow-up of 16 ± 19 and 15 ± 21 months, respectively (p = 0.76). Based on maximum color Doppler diameter, in TNs, ASD resolution occurred in 95% of small (3-5 mm), 87% of moderate (5.1-8 mm), and 60% of large (> 8 mm) defects; whereas, in PNs, resolution occurred in 79% of small, 76% of moderate, and 33% of large ASDs. There was a significant association between size and ASD resolution in TNs (p = 0.003), but not PNs (p = 0.17). Overall, ASD resolution rate was higher in TNs (89%) versus PNs (78%) (p = 0.009), and fewer TNs (1%) compared to PNs (7%) required ASD intervention (p = 0.02). Most ASDs identified in TNs and PNs spontaneously resolve. PNs, however, demonstrate lower ASD resolution and higher intervention rates within all size groups. These data should inform follow-up of affected neonates.


Assuntos
Comunicação Interatrial , Recém-Nascido , Humanos , Comunicação Interatrial/diagnóstico por imagem , Ecocardiografia , Ultrassonografia Doppler em Cores , Resultado do Tratamento , Cateterismo Cardíaco
10.
J Pediatr Hematol Oncol ; 46(3): e233-e240, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38408130

RESUMO

OBJECTIVE: To investigate superb microvascular imaging (SMI), a novel Doppler ultrasound technique that can visualize low-velocity microvascular flow, for assessing pediatric focal nodular hyperplasia (FNH). PATIENTS AND METHODS: Nine FNH lesions in 6 patients were enrolled. On SMI and color Doppler imaging (CDI), intralesional vascularity was assessed visually and categorized as typical spoke-wheel pattern (central vessel radiating from the center to the periphery), multifocal spoke-wheel pattern, and nonspecific pattern. We compared the vascular features of the lesions between SMI and CDI and evaluated vascular patterns according to lesion size. RESULTS: In terms of vascularity pattern, the typical spoke-wheel pattern of FNH was noted more frequently on SMI (67%) than on CDI (11%; P < 0.05). In addition, a multifocal spoke-wheel pattern was noted in all remaining lesions (33%) on SMI. On the contrary, a nonspecific vascular pattern was detected in the majority (78%) of CDI. Regarding the lesion size and vascularity on SMI, the typical spoke-wheel pattern was seen more frequently in the small FNH group than in the large FNH group. The intralesional vascular signal was detected more frequently on SMI (100%) than on CDI (89%). CONCLUSION: SMI is feasible in evaluating FNH in children and has a greater ability to demonstrate the spoke-wheel pattern than CDI.


Assuntos
Hiperplasia Nodular Focal do Fígado , Humanos , Criança , Hiperplasia Nodular Focal do Fígado/diagnóstico por imagem , Hiperplasia Nodular Focal do Fígado/patologia , Meios de Contraste , Diagnóstico Diferencial , Ultrassonografia , Ultrassonografia Doppler em Cores/métodos
11.
Br J Radiol ; 97(1154): 377-385, 2024 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-38302083

RESUMO

OBJECTIVE: To evaluate the value of multimodal ultrasonography (US) in a rat experimental torsion model after 6 h of torsion with different degrees. METHODS: Twenty-one male rats were divided into three groups. Left testes of the rats were twisted around their vascular pedicle 360 degrees in group 1, 720 degrees in group 2, and 1080 degrees in group 3 and intact right testes of the rats were accepted as control group. Grey-scale US, superb microvascular imaging (SMI), colour Doppler ultrasonography (CDUS), strain elastography (SE), and two-dimensional (2-D) shear wave elastography (SWE) examinations were applied 6 h after torsion procedure and testes were removed for pathological evaluation. RESULTS: Short-axis dimensions and volumes of the torsion side were higher than control testes. Lengths of the testes in the 3rd torsion group were smaller than the testes in groups 1 and 2 (P < 0.002). SMI was better than CDUS in recognizing blood flow in testicular tissue. Strain ratios were higher in group 1 and decreased with the increasing torsion degree. Emean and standard deviation (SD) measurements increased in the torsion side. Pathologically the mean testicular damage scores were statistically significant between torsion and control testes in all groups. CONCLUSION: Our results showed that short-axis and volume measurements, SMI, 2D-SWE, and SE are effective in the evaluation and diagnosis of testicular torsion (TT). ADVANCES IN KNOWLEDGE: Evaluation of affected testis and intact testis with multiparametric US in late presenting TT cases is more reliable than being dependent on a single sonographic modality.


Assuntos
Técnicas de Imagem por Elasticidade , Torção do Cordão Espermático , Humanos , Ratos , Masculino , Animais , Torção do Cordão Espermático/diagnóstico por imagem , Testículo/diagnóstico por imagem , Testículo/irrigação sanguínea , Ultrassonografia , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Doppler em Cores
12.
Clin Radiol ; 79(4): e560-e566, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38336532

RESUMO

AIM: To compare the efficacy of quantitative contrast-enhanced ultrasonography (CEUS) analysis and colour Doppler ultrasound (CDU) in evaluating central retinal artery (CRA) microcirculation in patients with diabetes mellitus (DM). MATERIALS AND METHODS: In this prospective study, a total of 55 patients (98 eyes) with DM were enrolled as the study group. They were compared to 46 age-matched healthy volunteers (92 eyes) who were selected as the control group. Each patient underwent CDU and subsequent CEUS examination. CDU and quantitative CEUS parameters were evaluated. The diagnostic efficiency of the diagnostic performance of CEUS and CDU was evaluated and compared, and the scale thresholds of predictive indicators for the diagnosis of proliferative diabetic retinopathy (PDR) were evaluated using receiver operating characteristics (ROC) curve analyses. RESULTS: Group pairwise comparisons showed that the end diastolic velocity (EDV) and arrival time (AT) of CRA were significant predictors for PDR by CDU and by quantitative CEUS analysis, respectively (all p<0.05). The ROC curve analysis showed that the area under the curve value of AT was significantly higher than that of EDV (0.875 versus 0.634, p=0.0002). Accordingly, an AT cut-off value of 1.07 seconds resulted a sensitivity of 90.62 % and a specificity of 79.31 %. CONCLUSION: Quantitative CEUS analysis can improve the accuracy of clinical staging of diabetic retinopathy for the patients with DM, and the AT showed the best diagnostic efficiency.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Artéria Retiniana , Humanos , Artéria Retiniana/diagnóstico por imagem , Retinopatia Diabética/diagnóstico por imagem , Microcirculação , Estudos Prospectivos , Cor , Ultrassonografia Doppler em Cores/métodos , Ultrassonografia , Meios de Contraste
13.
BMC Ophthalmol ; 24(1): 89, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38413884

RESUMO

BACKGROUND: To evaluate the changes in retrobulbar circulation after strabismus surgery and to assess the relationship of these changes with choroidal thickness (CT). METHODS: This prospective study included 26 eyes of 26 patients who underwent strabismus surgery and 15 eyes of 15 healthy individuals as control group. The patients who had single horizontal muscle surgery were included in Group 1 (n = 14); and those who had surgery on both horizontal muscles were included in Group 2 (n = 12). Peak systolic velocity (PSV), end-diastolic velocity (EDV), resistive index (RI) and pulsatility index (PI) of ophthalmic artery (OA), posterior ciliary artery (PCA), and central retinal artery (CRA) were measured using Color Doppler Ultrasonography. Subfoveal CT was measured via Optical Coherence Tomography. All measurements were obtained preoperatively, at 1st week and 1st month after surgery. RESULTS: There were no differences regarding preoperative blood flow velocity parameters among the groups. OA RI increased significantly at 1st week and 1st month after surgery in Group 1 and 2 (P = 0.029 and P = 0.045, respectively). There was a significant increase in PCA PSV at 1st week in Group 1 (P = 0.002). There was no difference between the mean preoperative and postoperative CT among the 3 groups. A negative correlation between the percentage changes of CT and CRA EDV was found in Group 2 (P = 0.011). CONCLUSION: Single and double horizontal rectus muscle surgery have a measurable effect on retrobulbar hemodynamics but these changes do not correlate with CT.


Assuntos
Artéria Retiniana , Estrabismo , Humanos , Estudos Prospectivos , Órbita , Hemodinâmica/fisiologia , Artéria Retiniana/diagnóstico por imagem , Artéria Oftálmica , Velocidade do Fluxo Sanguíneo/fisiologia , Corioide , Ultrassonografia Doppler em Cores/métodos , Estrabismo/cirurgia
14.
Ultrasound Med Biol ; 50(5): 671-679, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38331697

RESUMO

OBJECTIVE: The color Doppler twinkling artifact has been attributed to existing microbubbles or cavitation occurring on rough objects such as kidney stones, some breast biopsy clips, catheter guidewires and sandpaper. The objective was to investigate the correlation between the surface characteristics of helical constructs with different groove geometries and the occurrence of twinkling, as well as to identify locations conducive to bubble retention and/or cavitation. METHODS: Six half-cylinders were created with a microscale 3-D printer with 5 µm resolution to replicate the geometry of twinkling helical constructs resembling catheter guidewires. Four copies of each marker including a non-twinkling control were printed. The half-cylinders had pitch (peak-to-peak distance) values ranging from 87.5 to 343 µm and amplitude (groove depth) values ranging from 41.5 to 209 µm. The half-cylinders were submerged in degassed water and optically imaged before and after ultrasound insonification to visualize bubbles on the cylinders. The cylinders remained submerged while scanning with the color Doppler mode at frequencies from 3.1 to 6.3 MHz using a GE Logiq E9 scanner and 9L linear array transducer. RESULTS: Two markers exhibited twinkling: one with pitch-to-amplitude ratio of 174/210 µm/µm (0.8) that twinkled only with pre-existing bubbles on the marker; the other had a ratio of 87/87 µm/µm (1.00) that twinkled without pre-existing bubbles on the marker. CONCLUSION: This work provides strong evidence that both existing bubbles and either cavitation or ultrasound wave interactions with patterned or rough surfaces are significant factors in producing the twinkling signature.


Assuntos
Cálculos Renais , Humanos , Cálculos Renais/patologia , Ultrassonografia , Ultrassonografia Doppler em Cores/métodos , Imagens de Fantasmas , Microbolhas , Artefatos
15.
BMC Ophthalmol ; 24(1): 64, 2024 Feb 13.
Artigo em Inglês | MEDLINE | ID: mdl-38350897

RESUMO

OBJECTIVE: To evaluate the alterations in retrobulbar color Doppler imaging (CDI) parameters and retinal/choroidal optical coherence tomography angiography (OCTA) parameters and their association with the clinical activity and severity in thyroid-associated orbitopathy (TAO) patients. METHODS: In this study, the retrobulbar flow parameters including resistance index (RI), Pulsatile Index(PI), peak systolic velocity (PSV) and end diastolic velocity (EDV) in posterior ciliary artery (PCA), central retinal artery (CRA) and ophthalmic artery (OA) were determined by CDI. Moreover, the retina and choroidal vascularity including the superficial vessel density (SVD), deep vessel density (DVD), choroidal thickness (ChT) and choroidal vascularity, including total choroidal area (TCA), luminal area (LA), stromal area (SA) and Choroidal Vascularity Index (CVI), were determined by OCTA. All patients grouped as active TAO and inactive TAO based on Clinical activity score (CAS). We picked the severe eye among the subjects and compared all parameters between two groups. We analyzed the correlations among those parameters. RESULTS: There was a significant difference in CAS score, proptosis value, ChT, LA, CVI between patients with active TAO and inactive TAO. In the active group, PSV and EDV of PCA were significantly higher than the inactive group. On logistic regression analysis, CAS was closely associated with PSV-PCA. On multiple linear regression, proptosis value was closely associated with ChT, LA, SA and CVI. CONCLUSION: Choroidal vascularization and retrobulbar blood flow were concurrently higher in active TAO patients and several variables in choroid circulation was closely related to TAO clinical features.


Assuntos
Oftalmopatia de Graves , Humanos , Estudos Transversais , Órbita/diagnóstico por imagem , Artéria Oftálmica/diagnóstico por imagem , Corioide , Ultrassonografia Doppler em Cores/métodos , Velocidade do Fluxo Sanguíneo/fisiologia
16.
J Vis Exp ; (204)2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38407262

RESUMO

This paper proposes a novel thyroid examination technique based on five-dimensional (5D) synchronous reconstruction of ultrasound data. The raw temporal sequences are reconstructed into 3D volumetric data reflecting anatomical structure. Triplanar visualization from three orthogonal planes is realized to provide a systematic inspection of the entire gland. Color Doppler imaging is integrated into each triplanar slice to map vascularity changes. This multi-modal fusion enables synchronous display of structural, functional, and blood flow information in the reconstructed 5D space. Compared to conventional scanning, this technique offers the benefits of flexible offline diagnosis, reduced dependency on scanning, enhanced intuitive interpretation, and comprehensive multi-aspect evaluation. By minimizing oversight errors, it could improve diagnostic accuracy, especially for novice practitioners. The proposed 5D fusion method allows rapid and precise localization of lesions for early detection. Future work will explore integration with biochemical markers to further improve diagnostic precision. The technique has considerable clinical value for advancing thyroid examination.


Assuntos
Glândula Tireoide , Ultrassonografia Doppler em Cores , Glândula Tireoide/diagnóstico por imagem
17.
J Appl Clin Med Phys ; 25(3): e14298, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38373294

RESUMO

PURPOSE: Diagnosing Renal artery stenosis (RAS) presents challenges. This research aimed to develop a deep learning model for the computer-aided diagnosis of RAS, utilizing multimodal fusion technology based on ultrasound scanning images, spectral waveforms, and clinical information. METHODS: A total of 1485 patients received renal artery ultrasonography from Peking Union Medical College Hospital were included and their color doppler sonography (CDS) images were classified according to anatomical site and left-right orientation. The RAS diagnosis was modeled as a process involving feature extraction and multimodal fusion. Three deep learning (DL) models (ResNeSt, ResNet, and XCiT) were trained on a multimodal dataset consisted of CDS images, spectrum waveform images, and individual basic information. Predicted performance of different models were compared with senior physician and evaluated on a test dataset (N = 117 patients) with renal artery angiography results. RESULTS: Sample sizes of training and validation datasets were 3292 and 169 respectively. On test data (N = 676 samples), predicted accuracies of three DL models were more than 80% and the ResNeSt achieved the accuracy 83.49% ± 0.45%, precision 81.89% ± 3.00%, and recall 76.97% ± 3.7%. There was no significant difference between the accuracy of ResNeSt and ResNet (82.84% ± 1.52%), and the ResNeSt was higher than the XCiT (80.71% ± 2.23%, p < 0.05). Compared to the gold standard, renal artery angiography, the accuracy of ResNest model was 78.25% ± 1.62%, which was inferior to the senior physician (90.09%). Besides, compared to the multimodal fusion model, the performance of single-modal model on spectrum waveform images was relatively lower. CONCLUSION: The DL multimodal fusion model shows promising results in assisting RAS diagnosis.


Assuntos
Aprendizado Profundo , Obstrução da Artéria Renal , Humanos , Obstrução da Artéria Renal/diagnóstico por imagem , Angiografia , Ultrassonografia Doppler em Cores/métodos
18.
J Clin Ultrasound ; 52(4): 442-444, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38407455

RESUMO

We describe a rare case of Mondor disease of the superficial scrotal veins, which can clinically mimic acute testicular pathologies such as testicular torsion or epididymo-orchitis, and highlight the value of grayscale/Doppler ultrasound examination in distinguishing these entities, which have different management implications.


Assuntos
Escroto , Humanos , Masculino , Escroto/diagnóstico por imagem , Escroto/irrigação sanguínea , Diagnóstico Diferencial , Torção do Cordão Espermático/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Orquite/diagnóstico por imagem , Doença Aguda , Adulto , Veias/diagnóstico por imagem , Emergências , Ultrassonografia Doppler/métodos
19.
J Ultrasound Med ; 43(6): 1045-1051, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38356337

RESUMO

OBJECTIVES: The aim of this study was to establish the relationship of facial artery with nasolabial fold by color Doppler sonography and to determine facial artery variations and their relationship with age, gender, or hemifaces. METHODS: The study included 188 patients (94 women, 94 men) aged 18-60 years. Overall, 376 facial arteries in both hemifaces were evaluated for the course within nasolabial fold, symmetry, and relationship with gender. RESULTS: The mean age of the patients was 39.29 ± 12.81 years. Type A (55.7%) was the most common type in both hemifaces. There was no significant relationship between the course of facial artery and age (P > .05). Asymmetrical course of facial artery was more common in females (54.3%). In both genders, type A was the type with highest symmetry detected. CONCLUSIONS: Nasolabial fold is one of the important facial regions for filler injection. To prevent vascular injection, course of facial artery should be identified within the nasolabial fold. Type A was the most common type in both hemifaces and genders. Although the rates were close to each other, asymmetry in the course of the facial artery was observed in most of the patients. Ultrasonographic examination which is non-invasive and non-ionizing imaging method can be performed carefully before filler injection to determine vascular tissues.


Assuntos
Artérias , Face , Sulco Nasogeniano , Ultrassonografia Doppler em Cores , Humanos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade , Adolescente , Sulco Nasogeniano/diagnóstico por imagem , Adulto Jovem , Face/irrigação sanguínea , Face/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Artérias/diagnóstico por imagem , Fatores Sexuais
20.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(1): 1-5, 2024 Jan 30.
Artigo em Chinês | MEDLINE | ID: mdl-38384208

RESUMO

Vector flow imaging (VFI) is an innovative ultrasound flow measurement technology. Compared with the traditional color Doppler and spectral Doppler, VFI has the advantages of independence of angle correction and direct acquisition of real-time amplitude and direction of flow. Transverse oscillation (TO) method is one of the effective methods for vector flow imaging. However, a complete and detailed algorithm validation process based on commercial ultrasound machines is still lacking due to more complex convex probes. This study starts with introducing the imaging process and principle of transverse oscillation vector flow technique, and calculates the error between the set velocity value and the measured velocity value through the simulation experiment, and verifies the error between the set velocity value and the measured velocity value through the Doppler flow phantom experiment. Among them, the velocity value measured by the TO vector flow technique in the simulation experiment is 0.48 m/s and the preset value is 0.50 m/s, the error between them is -4%. The velocity values are 8.33, 11.14, 14.44 and 16.67 cm/s measured by the Doppler flow phantom experiment, the actual velocity values are 7.97, 10.78, 14.06 and 17.34 cm/s, the errors between them are all within ±5%. Both experiments verify the feasibility of using vector flow technique on abdominal convex probe.


Assuntos
Abdome , Ultrassom , Velocidade do Fluxo Sanguíneo , Ultrassonografia , Abdome/diagnóstico por imagem , Imagens de Fantasmas , Ultrassonografia Doppler em Cores
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...